Skip to content
by Renogy

Renogy Battery Shunt 300

Renogy Battery Shunt 300

SKU RSHST-B02P300-US
Save $20.00 Save $20.00
Original price $156.99
Original price $156.99 - Original price $156.99
Original price $156.99
Current price $136.99
$136.99 - $136.99
Current price $136.99
Availability:
in stock, ready to be shipped

Free shipping with delivery betweenandOrder within

Free Shipping

Every Off Grid Stores Product Ships For Free

No Sales Tax Many States

We Charge Sales Tax Only In AZ, CA, CO, FL, GA, MI, NC, NV, OH, PA, TN, TX, VA, and WA

Authorized Dealer

We are authorized dealers of every brand on our website

1-Year Warranty

Off Grid Stores is an authorized retailer of Renogy products. Because of this, we pass on Renogy's manufacturer warranty to you.

Product Highlights
  • Remote monitoring and control via Renogy ONE/DC Home App.
  • Compatible with various batteries: Lead Acid, LFP, Li-ion, and Ni-MH.
  • Displays State of Charge, temperature, and starter battery voltage.
  • Records historical data and issues alerts via DC Home app.
  • Not compatible with Renogy ONE M1 currently.
Why Buy From Us?

- Help Support Small Family Owned Business

- Our Team Has Actual Knowledge Of Our Products

- You Will Talk To A Real Person In The USA When You Call

- We Guarantee To Match The Lowest Prices On The Internet

- Our Items Are Located In The USA

- We Actually Live Off-Grid Unlike Some Of Our Competitors

Best Price Guarantee

Shop with confidence, as we guarantee the best prices available.

If you come across an item at a lower price on a competitor's website, we'll gladly match it.

Simply contact our customer service chat before purchasing to redeem this exclusive offer.

Learn more by visiting our Best Price Guarantee page here.

Shipping & Handling Policy

We provide Free Shipping to the continental 48 United States only.

International shipping, as well as shipping to Alaska, Hawaii, US Protectorates, P.O. Boxes, APO, FPO, or DPO addresses, is NOT available.

Orders are typically processed and shipped from our warehouse within 1-3 Business Days (excluding weekends and holidays).

After leaving our warehouse, the expected delivery time is 3-4 Business Days, resulting in an average total shipping and handling time of 4-7 Business Days.

Learn more about our Shipping & Handling Policy here.

Returns & Refunds

While shopping at Off Grid Stores know that returns are a breeze! If you are not completely satisfied with your purchase, for any reason, you may return it to us within 30 Days of delivery for a refund.

If you would like to open up a return you can send us an email to support@offgridstores.com with your name, order number, and reason for return.

To learn more about our Returns & Refunds Policy you can do so here.

Renogy Battery Shunt 300

Renogy Battery Shunt 300

Check Your Battery Charging Level Anytime Anywhere

Ensures precise battery monitoring via the Renogy ONE Core and DC Home App.

Effortless Installation in 5 Minutes

It can be placed on top of the battery or securely mounted on the wall with screws. The connection points feature protective covers to effectively safeguard against any loosening caused by various movements.

Fast Connection in 4 Steps

When paired with Renogy ONE Core and DC Home, the Shunt 300 provides a seamless real-time data display experience.

Quick Setup Involves Simple Operations to Get Started

The initial steps for a quick setup are designed to be user-friendly and straightforward, ensuring that users can get started with ease.

Specifications:

Renogy Battery Shunt 300
SKU RSHST-B02P300-US
ELECTRICAL DATA
Model Name RSHST-B02P300-G1
Power Supply 8 - 120 VDC
Power Consumption <0.1 W
Communication Bluetooth LE and BLE Mesh
Max continuous current 300A
Max peak current 500A(<10s)
Current accuracy ±1%
Current Resolution 0.01 A
Battery Capacity 1 - 6500Ah
Voltage Input Range 8 - 60V
Voltage input resolution 10 mV
Temperature sensor range -4°F~176°F
Temperature sensor accuracy ±1%
Operating Temperature -4℉~122℉
Operating Humidity 0% to 95% RH
Operating Altitude Less than 2000m above sea level
Installation mounted on the wall
Battery connection M10 bolts
Weight 0.57 lbs
Dimensions 5.27 in x 3.82 in x 1.22 in
Certifications CE, FCC ID,IC ID,RCM,
TSCA, RoHS,UN38.3,TELEC

Frequently Asked Questions

Incorrect temperature reading

Confirm the Battery Temperature Sensor is properly installed.

Incorrect SOC reading

The battery capacity decreases as the charging and discharging cycles increase.Re-configure the “Rated Battery Ah” to the capacity when the battery is fully charged.

Inaccurate sampling precision in large-current scenarios

Elevated ambient temperatures can affect sampling accuracy. Ensure proper ventilation for the shunt and remove the upper cover if needed.

What should I do if my Battery Shunt 300 is showing only discharging readings?

If you notice that your Battery Shunt 300 displays only discharging readings after installation, with the readings staying at zero, please follow these steps: 1.Remove Battery Shunt from both Renogy One Core and DC Home. 2. Uninstall the DC Home app and install a new DC Home app. 3. To avoid potential conflicts, turn off your phone before proceeding. 4.Set Renogy One Core to pairing mode and reset the Battery Shunt. 5.Pair Renogy One Core and Battery Shunt 300, then turn on your phone. 6.Activate pairing in DC Home; you will see a link, not the Battery Shunt 300 readings. However, this link is pairing Battery Shunt 300 and Renogy One Core with DC Home. 7. Pair this link. By following these steps,you can resolve the issue, and the Battery Shunt 300 readings displayed correctly. If the issue persists, it's recommended to contact Renogy's technical support for further assistance.

Why does the SOC alarm parameter on my Battery Shunt reset to 50% in Renogy Core One settings?

If you're experiencing an issue where the State of Charge (SOC) alarm parameter you set for the Battery Shunt in Renogy Core One settings resets to 50% after a short period, follow these steps for troubleshooting: 1.Turn off the power to the Battery Shunt 300. 2.Delete the Battery Shunt 300 from the Renogy One Core settings. 3.Turn the power back on for the Battery Shunt 300. 4.Add the Battery Shunt 300 back to the Renogy One Core. 5.Refer to the user manual for the Battery Shunt 300 and follow the provided instructions for setting up the SOC alarm parameter. By following these troubleshooting steps, you can resolve the issue of the SOC alarm parameter resetting to the default value.If the issue persists, it's recommended to contact Renogy's technical support for further assistance.

What should I do if my Battery Shunt 300 can connect to my phone but not to Renogy One Core?

If your Battery Shunt successfully connects to your phone but faces issues connecting to Renogy One Core, consider the following steps: 1.Check Renogy One Core Firmware 2.Reset the Battery Shunt 300:Press and hold the reset button on the Battery Shunt for 5 seconds until the Bluetooth light turns off. 3.Connection Steps:On the Renogy One Core, click "Add Device" and scan for the Battery Shunt 300.Once detected, the Battery Shunt's Bluetooth light should stay solid. By following these troubleshooting steps, you can resolve issues related to Battery Shunt connectivity with the Renogy One Core. If problems persist, contact Renogy's technical support for further assistance.

Battery charge percentage doesn’t show and the Consumed Ah reading is way off.

If you encounter abnormal data readings on the Battery Shunt 300, follow these troubleshooting steps: 1.Power off the Battery Shunt 300 and restart it. 2.Perform charge and discharge cycles on the battery pack connected to the Battery Shunt 300. 3.After the restart and cycling, check if the consumed Ampere-Hours (AH) reading returns to normal. If the issue persists after the above steps, please contact our support team for further assistance.

The Battery Shunt 300 doesn't have programming options for lithium or lead-acid batteries. Can it not be programmed for lithium or lead-acid batteries?

Battery Shunt 300 does not differentiate between battery types. Its calculations are based on current and voltage. During the initial connection, it will prompt you to input the battery capacity. It can also be manually calibrated. After fully charging the battery, set the current SOC to 100% in the settings.While specific programming for different battery types isn't available, these settings and manual adjustments ensure precise monitoring and control.

Can the Battery Shunt 300 handle battery banks larger than 300A?

The 300A specification of the Battery Shunt represents its maximum capacity rather than indicating a limitation based on battery bank size. It is not restricted to use only with 300A battery banks. To ensure compatibility, calculate the actual maximum continuous current in your circuit, and the Battery Shunt 300 should be suitable for monitoring larger battery banks.

User Manuals & Files:

Renogy Battery Shunt 300 User Manual

download
Download Now >

Renogy Battery Shunt 300 Specification Sheet

download
Download Now >

Customer Reviews

Based on 1 review
0%
(0)
0%
(0)
100%
(1)
0%
(0)
0%
(0)
E
Eric S.
Good product, poor documentation. Shipping by Renogy took more than a week.

The Renogy smart shunt works well. When it alarms, though, you need to jump through some hoops on the Renogy OneCore or DC Home app to reset it. NOTHING in the manuals from Renogy regarding this, which is typical of Renogy's poor and confusing and incomplete documentation. Desperation led me to turn off the alarm all together in settings, and then turn it back on. Finally the beeping stopped! Shipping took more than a week because the first time I was notified that it had shipped, UPS NEVER received it. I had to bug OffGrid and they sent a second one which only took 3 days after "shipped" notification for UPS to actually have it in hand. Looking at the label, it was drop-shipped directly from Renogy, so Renogy is the slow shipping culprit, not OffGrid. Thanks to OffGrid for ordering a second unit right away.