{"product_id":"24v-230ah-v2-t-elite-series-lifepo4-battery-5-89kwh","title":"Epoch Batteries 24V 230Ah V2-T Elite Series LiFePO4 Battery (5.89kWh)","description":"\u003cdiv style=\"font-family: 'Inter', -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, 'Helvetica Neue', Arial, sans-serif; font-size: 15px; line-height: 1.6; color: #2d3748; text-transform: none; max-width: 1100px; margin: 0 auto;\"\u003e\n\u003c!-- Hero --\u003e\n\u003csection style=\"background: linear-gradient(135deg,#031725 0%,#06253D 62%,#02111F 100%); color: #ffffff; padding: 34px 26px; border-radius: 14px; margin-bottom: 24px; border: 1px solid rgba(46,145,229,0.35); box-shadow: 0 14px 34px rgba(6,37,61,0.16);\"\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(260px,1fr)); gap: 24px; align-items: center;\"\u003e\n\u003cdiv\u003e\n\u003cp style=\"margin: 0 0 10px 0; color: #7dc8ff; font-size: 12px; font-weight: bold; letter-spacing: 0.14em; text-transform: uppercase;\"\u003e \u003c\/p\u003e\n\u003cp style=\"margin: 0 0 10px 0; color: #7dc8ff; font-size: 12px; font-weight: bold; letter-spacing: 0.14em; text-transform: uppercase;\"\u003eClass-T protection · Victron CAN · Heated · Bluetooth\u003c\/p\u003e\n\u003ch1 style=\"margin: 0; color: #ffffff; font-size: 34px; line-height: 1.14; font-weight: bold; letter-spacing: -0.02em; text-transform: none;\"\u003eEpoch 24V 230Ah V2-T Elite Series LiFePO4 | Built-In Fuse, Victron \u0026amp; BT\u003c\/h1\u003e\n\u003cp style=\"margin: 12px 0 0 0; color: #d9ecff; font-size: 16px; line-height: 1.55; max-width: 800px;\"\u003eA premium 5.89kWh lithium battery for advanced marine, RV, Victron, and 24V off-grid solar systems.\u003c\/p\u003e\n\u003cp style=\"margin: 18px 0 0 0; color: #ffffff; max-width: 900px;\"\u003eThe Epoch 24V 230Ah V2-T Elite is a high-capacity 24V 230Ah LiFePO4 battery engineered around a user-serviceable 300A Class-T fuse, native Victron CANBus communication, internal heating, Bluetooth monitoring, and an IP67 enclosure. Its 5.89kWh energy platform gives system builders a compact, managed battery for demanding marine house banks, RV power systems, and professional off-grid energy storage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003caside style=\"background: rgba(255,255,255,0.07); border: 1px solid rgba(46,145,229,0.45); border-radius: 12px; padding: 22px;\"\u003e\n\u003cp style=\"margin: 0; color: #ffffff; font-size: 20px; line-height: 1.35; font-weight: bold;\"\u003eHigh-capacity 24V power with protection built at the source.\u003c\/p\u003e\n\u003cdiv style=\"height: 1px; background: rgba(125,200,255,0.45); margin: 18px 0;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp style=\"margin: 0; color: #d9ecff; font-size: 13px; letter-spacing: 0.08em; text-transform: uppercase;\"\u003eV2-T Elite Series · C24230A-A\u003c\/p\u003e\n\u003c\/aside\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Quick specs --\u003e\n\u003csection style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(145px,1fr)); gap: 12px; margin-bottom: 28px;\"\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 12px; padding: 18px; text-align: center; box-shadow: 0 4px 16px rgba(6,37,61,0.05);\"\u003e\n\u003cdiv style=\"color: #1a202c; font-size: 26px; line-height: 1; font-weight: bold; letter-spacing: -0.02em;\"\u003e230Ah\u003c\/div\u003e\n\u003cdiv style=\"color: #2e91e5; font-size: 12px; font-weight: bold; letter-spacing: 0.12em; text-transform: uppercase; margin-top: 8px;\"\u003eCapacity\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 12px; padding: 18px; text-align: center; box-shadow: 0 4px 16px rgba(6,37,61,0.05);\"\u003e\n\u003cdiv style=\"color: #1a202c; font-size: 26px; line-height: 1; font-weight: bold; letter-spacing: -0.02em;\"\u003e5.89kWh\u003c\/div\u003e\n\u003cdiv style=\"color: #2e91e5; font-size: 12px; font-weight: bold; letter-spacing: 0.12em; text-transform: uppercase; margin-top: 8px;\"\u003eStored energy\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 12px; padding: 18px; text-align: center; box-shadow: 0 4px 16px rgba(6,37,61,0.05);\"\u003e\n\u003cdiv style=\"color: #1a202c; font-size: 26px; line-height: 1; font-weight: bold; letter-spacing: -0.02em;\"\u003e115A\u003c\/div\u003e\n\u003cdiv style=\"color: #2e91e5; font-size: 12px; font-weight: bold; letter-spacing: 0.12em; text-transform: uppercase; margin-top: 8px;\"\u003eContinuous output\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 12px; padding: 18px; text-align: center; box-shadow: 0 4px 16px rgba(6,37,61,0.05);\"\u003e\n\u003cdiv style=\"color: #1a202c; font-size: 26px; line-height: 1; font-weight: bold; letter-spacing: -0.02em;\"\u003e300A\u003c\/div\u003e\n\u003cdiv style=\"color: #2e91e5; font-size: 12px; font-weight: bold; letter-spacing: 0.12em; text-transform: uppercase; margin-top: 8px;\"\u003eClass-T fuse\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 12px; padding: 18px; text-align: center; box-shadow: 0 4px 16px rgba(6,37,61,0.05);\"\u003e\n\u003cdiv style=\"color: #1a202c; font-size: 26px; line-height: 1; font-weight: bold; letter-spacing: -0.02em;\"\u003eIP67\u003c\/div\u003e\n\u003cdiv style=\"color: #2e91e5; font-size: 12px; font-weight: bold; letter-spacing: 0.12em; text-transform: uppercase; margin-top: 8px;\"\u003eIngress rating\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 12px; padding: 18px; text-align: center; box-shadow: 0 4px 16px rgba(6,37,61,0.05);\"\u003e\n\u003cdiv style=\"color: #1a202c; font-size: 26px; line-height: 1; font-weight: bold; letter-spacing: -0.02em;\"\u003e16×\u003c\/div\u003e\n\u003cdiv style=\"color: #2e91e5; font-size: 12px; font-weight: bold; letter-spacing: 0.12em; text-transform: uppercase; margin-top: 8px;\"\u003eParallel limit\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Trust band --\u003e\n\u003csection style=\"background: #F7FAFC; border: 1px solid #E2E8F0; border-radius: 14px; padding: 22px; margin-bottom: 32px;\"\u003e\n\u003ch2 style=\"font-size: 18px; font-weight: 600; letter-spacing: 0.05em; text-transform: uppercase; color: #1a202c; margin: 0 0 12px 0; line-height: 1.35;\"\u003eBuilt for demanding 24V energy systems\u003c\/h2\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(145px,1fr)); gap: 10px;\"\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 10px; padding: 14px;\"\u003e\n\u003cstrong style=\"display: block; color: #1a202c; font-weight: 600;\"\u003e11-year limited warranty\u003c\/strong\u003e \u003cspan style=\"color: #4a5568;\"\u003e5 yrs free repair or replacement\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 10px; padding: 14px;\"\u003e\n\u003cstrong style=\"display: block; color: #1a202c; font-weight: 600;\"\u003eVictron ready\u003c\/strong\u003e \u003cspan style=\"color: #4a5568;\"\u003eCAN and DVCC integration\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 10px; padding: 14px;\"\u003e\n\u003cstrong style=\"display: block; color: #1a202c; font-weight: 600;\"\u003eInternal heating\u003c\/strong\u003e \u003cspan style=\"color: #4a5568;\"\u003eCold-weather charging support\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 10px; padding: 14px;\"\u003e\n\u003cstrong style=\"display: block; color: #1a202c; font-weight: 600;\"\u003eBluetooth monitoring\u003c\/strong\u003e \u003cspan style=\"color: #4a5568;\"\u003eEpoch Cloud app and included gauge\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 10px; padding: 14px;\"\u003e\n\u003cstrong style=\"display: block; color: #1a202c; font-weight: 600;\"\u003eCertified cells\u003c\/strong\u003e \u003cspan style=\"color: #4a5568;\"\u003eUL1642, UL9540A and IEC 62619:2022\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 10px; padding: 14px;\"\u003e\n\u003cstrong style=\"display: block; color: #1a202c; font-weight: 600;\"\u003eServiceable fuse\u003c\/strong\u003e \u003cspan style=\"color: #4a5568;\"\u003eProtected top access\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Intro --\u003e\n\u003csection style=\"margin-bottom: 30px;\"\u003e\n\u003ch2 style=\"font-size: 24px; font-weight: bold; letter-spacing: -0.01em; text-transform: none; color: #1a202c; margin: 0 0 12px 0; line-height: 1.25;\"\u003eA 5.89kWh Energy Vault for Marine and Off-Grid Systems\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 14px 0; color: #2e91e5; font-weight: 600;\"\u003ePremium 24V storage with source protection, managed communications, and scalable architecture.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 14px 0;\"\u003eThe V2-T platform is intended for deep-cycle house-power and energy-storage service rather than engine starting. One battery provides 230Ah at 25.6V nominal and supports large 24V loads without the complexity of wiring several smaller batteries in parallel.\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003eThe integrated fuse, CAN communication, remote gauge, external power control, heating, and Bluetooth monitoring reduce installation clutter—but installers must still provide the main disconnect, properly selected downstream overcurrent protection, branch fusing, busbars, conductors, securement, precharge where required, and a complete commissioning plan.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c!-- Safety section --\u003e\n\u003csection style=\"margin-bottom: 30px;\"\u003e\n\u003ch2 style=\"font-size: 24px; font-weight: bold; letter-spacing: -0.01em; text-transform: none; color: #1a202c; margin: 0 0 12px 0; line-height: 1.25;\"\u003eSafety: The V2-T Class T Fuse\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 14px 0; color: #2e91e5; font-weight: 600;\"\u003eHigh-interrupt source protection, managed BMS safeguards, and a sealed serviceable enclosure.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(280px,1fr)); gap: 18px; margin: 0 0 32px 0;\"\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 14px; padding: 22px;\"\u003e\n\u003ch3 style=\"font-size: 19px; font-weight: bold; color: #1a202c; margin: 0 0 10px 0; line-height: 1.3;\"\u003eUser-Serviceable 300A Class-T Fuse\u003c\/h3\u003e\n\u003cp style=\"margin: 0;\"\u003eThe Eaton Bussmann JJN-300 has a 20kA interrupting rating at 160V DC and sits under a protected service cover on the lid. It reduces fault energy at the battery outlet, but it does not replace the main disconnect or downstream cable and branch protection: install a DC-rated fuse or breaker in the positive conductor, as close to the battery as practical.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 14px; padding: 22px;\"\u003e\n\u003ch3 style=\"font-size: 19px; font-weight: bold; color: #1a202c; margin: 0 0 10px 0; line-height: 1.3;\"\u003eAdvanced BMS and Published Safety Listings\u003c\/h3\u003e\n\u003cp style=\"margin: 0;\"\u003eThe embedded BMS supervises cell voltage, current, temperature, protection events, and balancing. Epoch publishes UL1642, UL9540A, and IEC 62619:2022 cell references, plus CE, RoHS, and fuse-related listing information.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 14px; padding: 22px;\"\u003e\n\u003ch3 style=\"font-size: 19px; font-weight: bold; color: #1a202c; margin: 0 0 10px 0; line-height: 1.3;\"\u003eIP67 Dust-Tight, Immersion-Rated Enclosure\u003c\/h3\u003e\n\u003cp style=\"margin: 0;\"\u003eThe enclosure is dust-tight and rated for temporary immersion up to 1 meter for up to 30 minutes when every seal and gland is correctly installed. Treat IP67 as an ingress-protection test rating—not permission for permanent submersion, standing-water installation, water jets or pressure washing. Install the battery where it stays dry in normal use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Smart features --\u003e\n\u003csection style=\"margin-bottom: 30px;\"\u003e\n\u003ch2 style=\"font-size: 24px; font-weight: bold; letter-spacing: -0.01em; text-transform: none; color: #1a202c; margin: 0 0 12px 0; line-height: 1.25;\"\u003ePremium Smart Features and Seamless Integration\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 14px 0; color: #2e91e5; font-weight: 600;\"\u003eManaged Victron charging, cold-weather operation, and real-time battery visibility.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(280px,1fr)); gap: 18px; margin: 0 0 32px 0;\"\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 14px; padding: 22px;\"\u003e\n\u003ch3 style=\"font-size: 19px; font-weight: bold; color: #1a202c; margin: 0 0 10px 0; line-height: 1.3;\"\u003eNative Victron Integration via CANBus\u003c\/h3\u003e\n\u003cp style=\"margin: 0;\"\u003eThe BMS communicates at 500kbit\/s through the specified battery harness. A correctly configured Cerbo GX or Ekrano GX can use Epoch as the controlling BMS and battery monitor with DVCC enabled, allowing the battery to publish managed operating data and charging limits to the Victron system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 14px; padding: 22px;\"\u003e\n\u003ch3 style=\"font-size: 19px; font-weight: bold; color: #1a202c; margin: 0 0 10px 0; line-height: 1.3;\"\u003eCold-Weather Ready with Internal Heating\u003c\/h3\u003e\n\u003cp style=\"margin: 0;\"\u003eThe 153.6W heater is controlled by the BMS. The cells are not charged below 0°C (32°F); while charging, the heater switches on at 5°C (41°F) and off at 10°C (50°F), using incoming charge energy to warm the cells before normal charging proceeds.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 14px; padding: 22px;\"\u003e\n\u003ch3 style=\"font-size: 19px; font-weight: bold; color: #1a202c; margin: 0 0 10px 0; line-height: 1.3;\"\u003eBluetooth App and Physical Monitoring\u003c\/h3\u003e\n\u003cp style=\"margin: 0;\"\u003eMonitor state of charge, cell voltage, temperature, charge and discharge cycles and system health alerts in the Epoch Cloud app (iOS and Android), over Bluetooth 4.0 through the included battery gauge. The included remote digital gauge and external power button provide local access without opening the battery compartment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Power and scalability --\u003e\n\u003csection style=\"margin-bottom: 30px;\"\u003e\n\u003ch2 style=\"font-size: 24px; font-weight: bold; letter-spacing: -0.01em; text-transform: none; color: #1a202c; margin: 0 0 12px 0; line-height: 1.25;\"\u003eUnrelenting Power and Massive Scalability\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 14px 0; color: #2e91e5; font-weight: 600;\"\u003eHigh-capacity standalone power with supported series or parallel expansion.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 14px 0;\"\u003eA single battery supports 115A continuous discharge (about 2,944W DC before inverter losses) and 250A for 5 seconds. Size inverters by their DC input current: a 2,000W load through a 90%-efficient inverter draws about 87A. If an inverter's continuous DC input can exceed 115A, add batteries in parallel. Uses include marine hotel loads, 24V trolling-motor and electric auxiliary systems where requirements match, and off-grid loads.\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003eScale to sixteen batteries in parallel for 3,680Ah and about 94.21kWh at 25.6V nominal, or use up to two matched batteries in series for a 51.2V nominal (48V-class) string, 58.0V at full charge. Mixed series-parallel banks are not supported.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c!-- Applications --\u003e\n\u003csection style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(280px,1fr)); gap: 22px; margin: 32px 0; align-items: start;\"\u003e\n\u003cdiv\u003e\n\u003ch2 style=\"font-size: 18px; font-weight: 600; letter-spacing: 0.05em; text-transform: uppercase; color: #1a202c; margin: 0 0 12px 0; line-height: 1.35;\"\u003eCompatible applications\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 14px 0; color: #2e91e5; font-weight: 600;\"\u003eMarine, Victron, RV, solar, off-grid, and high-capacity 24V power systems.\u003c\/p\u003e\n\u003cul style=\"list-style: none; padding: 0; margin: 0; display: grid; gap: 8px;\"\u003e\n\u003cli style=\"display: flex; gap: 9px; align-items: flex-start; margin: 0;\"\u003e\n\u003cspan style=\"color: #5ebb46; font-weight: 800; line-height: 1.6;\"\u003e✓\u003c\/span\u003e \u003cspan\u003e24V off-grid solar systems for cabins, remote sites, backup power, and stationary energy storage.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"display: flex; gap: 9px; align-items: flex-start; margin: 0;\"\u003e\n\u003cspan style=\"color: #5ebb46; font-weight: 800; line-height: 1.6;\"\u003e✓\u003c\/span\u003e \u003cspan\u003eVictron-based systems using compatible Cerbo GX or Ekrano GX devices and managed BMS communication.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"display: flex; gap: 9px; align-items: flex-start; margin: 0;\"\u003e\n\u003cspan style=\"color: #5ebb46; font-weight: 800; line-height: 1.6;\"\u003e✓\u003c\/span\u003e \u003cspan\u003eMarine house banks for electronics, refrigeration, pumps, navigation, lighting, and other hotel loads.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"display: flex; gap: 9px; align-items: flex-start; margin: 0;\"\u003e\n\u003cspan style=\"color: #5ebb46; font-weight: 800; line-height: 1.6;\"\u003e✓\u003c\/span\u003e \u003cspan\u003eLarge RV, expedition vehicle, and commercial mobile power systems using 24V inverter\/chargers.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"display: flex; gap: 9px; align-items: flex-start; margin: 0;\"\u003e\n\u003cspan style=\"color: #5ebb46; font-weight: 800; line-height: 1.6;\"\u003e✓\u003c\/span\u003e \u003cspan\u003e24V trolling-motor or electric auxiliary systems where current, voltage, charging, and manufacturer requirements match.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"display: flex; gap: 9px; align-items: flex-start; margin: 0;\"\u003e\n\u003cspan style=\"color: #5ebb46; font-weight: 800; line-height: 1.6;\"\u003e✓\u003c\/span\u003e \u003cspan\u003eReplacing a Group 8D lead-acid battery, after confirming tray fit, hold-down and lid clearance against 20.86 × 8.65 × 12.06 in.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"display: flex; gap: 9px; align-items: flex-start; margin: 0;\"\u003e\n\u003cspan style=\"color: #5ebb46; font-weight: 800; line-height: 1.6;\"\u003e✓\u003c\/span\u003e \u003cspan\u003eParallel banks up to sixteen batteries for larger 24V energy-storage systems.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"display: flex; gap: 9px; align-items: flex-start; margin: 0;\"\u003e\n\u003cspan style=\"color: #5ebb46; font-weight: 800; line-height: 1.6;\"\u003e✓\u003c\/span\u003e \u003cspan\u003eSeries strings of up to two batteries (51.2V nominal, 48V class), installed to the C24230A-A user manual.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003caside style=\"background: #FFF5F5; border: 1px solid #FED7D7; border-left: 5px solid #ED1B4A; border-radius: 12px; padding: 22px;\"\u003e\n\u003ch3 style=\"margin: 0 0 10px 0; color: #1a202c; font-size: 17px; line-height: 1.4; font-weight: bold; text-transform: none;\"\u003eDeep-cycle and installation boundary\u003c\/h3\u003e\n\u003cp style=\"margin: 0;\"\u003eThis battery is for house-power and energy-storage service, not engine cranking. The Class-T fuse is a source-protection feature, not a complete electrical system. Qualified installers must design the disconnect, downstream protection, branch circuits, conductors, mounting, charging, monitoring, and documentation.\u003c\/p\u003e\n\u003c\/aside\u003e\n\u003c\/section\u003e\n\u003c!-- Features --\u003e\n\u003csection style=\"margin-bottom: 32px;\"\u003e\n\u003ch2 style=\"font-size: 18px; font-weight: 600; letter-spacing: 0.05em; text-transform: uppercase; color: #1a202c; margin: 24px 0 12px 0; line-height: 1.35;\"\u003eV2-T Elite features\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 14px 0; color: #2e91e5; font-weight: 600;\"\u003eProfessional-grade source protection, communications, monitoring, and environmental capability.\u003c\/p\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(240px,1fr)); gap: 12px;\"\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 10px; padding: 17px; box-shadow: 0 4px 14px rgba(6,37,61,0.04);\"\u003e\n\u003cstrong style=\"display: block; color: #1a202c; font-weight: bold; margin-bottom: 5px;\"\u003e300A Eaton Class-T fuse\u003c\/strong\u003e \u003cspan style=\"color: #2d3748;\"\u003eUser-serviceable JJN-300 source fuse with a published 20kA interrupt rating at 160VDC.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 10px; padding: 17px; box-shadow: 0 4px 14px rgba(6,37,61,0.04);\"\u003e\n\u003cstrong style=\"display: block; color: #1a202c; font-weight: bold; margin-bottom: 5px;\"\u003e115A continuous discharge\u003c\/strong\u003e \u003cspan style=\"color: #2d3748;\"\u003eApproximately 2.94kW of nominal DC output from one 25.6V battery before conversion losses.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 10px; padding: 17px; box-shadow: 0 4px 14px rgba(6,37,61,0.04);\"\u003e\n\u003cstrong style=\"display: block; color: #1a202c; font-weight: bold; margin-bottom: 5px;\"\u003e115A continuous charging\u003c\/strong\u003e \u003cspan style=\"color: #2d3748;\"\u003e115A continuous (180A for 5 seconds) from lithium-compatible CC\/CV equipment programmed to 28.4V absorption and 27.0V float.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 10px; padding: 17px; box-shadow: 0 4px 14px rgba(6,37,61,0.04);\"\u003e\n\u003cstrong style=\"display: block; color: #1a202c; font-weight: bold; margin-bottom: 5px;\"\u003eVictron CAN communication\u003c\/strong\u003e \u003cspan style=\"color: #2d3748;\"\u003eManaged battery data and DVCC-based charge control through a correctly configured GX system.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 10px; padding: 17px; box-shadow: 0 4px 14px rgba(6,37,61,0.04);\"\u003e\n\u003cstrong style=\"display: block; color: #1a202c; font-weight: bold; margin-bottom: 5px;\"\u003eIP67 enclosure\u003c\/strong\u003e \u003cspan style=\"color: #2d3748;\"\u003eDust-tight and temporary-immersion rated when all seals and glands are properly installed.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 10px; padding: 17px; box-shadow: 0 4px 14px rgba(6,37,61,0.04);\"\u003e\n\u003cstrong style=\"display: block; color: #1a202c; font-weight: bold; margin-bottom: 5px;\"\u003e153.6W internal heater\u003c\/strong\u003e \u003cspan style=\"color: #2d3748;\"\u003eBMS-controlled 153.6W heater: on at 5°C and off at 10°C while charging; the cells are not charged below 0°C.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 10px; padding: 17px; box-shadow: 0 4px 14px rgba(6,37,61,0.04);\"\u003e\n\u003cstrong style=\"display: block; color: #1a202c; font-weight: bold; margin-bottom: 5px;\"\u003eBluetooth app monitoring\u003c\/strong\u003e \u003cspan style=\"color: #2d3748;\"\u003eTrack state of charge, cell voltage, temperature, cycles, and system alerts in the Epoch Cloud app.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 10px; padding: 17px; box-shadow: 0 4px 14px rgba(6,37,61,0.04);\"\u003e\n\u003cstrong style=\"display: block; color: #1a202c; font-weight: bold; margin-bottom: 5px;\"\u003eExternal controls included\u003c\/strong\u003e \u003cspan style=\"color: #2d3748;\"\u003eMountable power button and remote digital battery gauge simplify access and status checks.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 10px; padding: 17px; box-shadow: 0 4px 14px rgba(6,37,61,0.04);\"\u003e\n\u003cstrong style=\"display: block; color: #1a202c; font-weight: bold; margin-bottom: 5px;\"\u003eAdvanced BMS protection\u003c\/strong\u003e \u003cspan style=\"color: #2d3748;\"\u003eMonitors cell voltage, current, temperature, overcharge, over-discharge, and short-circuit conditions.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 10px; padding: 17px; box-shadow: 0 4px 14px rgba(6,37,61,0.04);\"\u003e\n\u003cstrong style=\"display: block; color: #1a202c; font-weight: bold; margin-bottom: 5px;\"\u003ePassive convection cooling\u003c\/strong\u003e \u003cspan style=\"color: #2d3748;\"\u003eNo liquid cooling loop or serviceable cooling fan required.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 10px; padding: 17px; box-shadow: 0 4px 14px rgba(6,37,61,0.04);\"\u003e\n\u003cstrong style=\"display: block; color: #1a202c; font-weight: bold; margin-bottom: 5px;\"\u003eSeries or parallel support\u003c\/strong\u003e \u003cspan style=\"color: #2d3748;\"\u003eUp to two in series or sixteen in parallel; mixed series-parallel is not supported.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 10px; padding: 17px; box-shadow: 0 4px 14px rgba(6,37,61,0.04);\"\u003e\n\u003cstrong style=\"display: block; color: #1a202c; font-weight: bold; margin-bottom: 5px;\"\u003eCertified components\u003c\/strong\u003e \u003cspan style=\"color: #2d3748;\"\u003ePublished UL1642\/UL9540A\/IEC 62619:2022 cell, CE, RoHS, and fuse-related listings.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Accessories --\u003e\n\u003csection style=\"background: #F7FAFC; border: 1px solid #E2E8F0; border-radius: 14px; padding: 22px; margin: 0 0 32px 0;\"\u003e\n\u003ch2 style=\"font-size: 18px; font-weight: 600; letter-spacing: 0.05em; text-transform: uppercase; color: #1a202c; margin: 0 0 12px 0; line-height: 1.35;\"\u003eRecommended system components\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 14px 0; color: #2e91e5; font-weight: 600;\"\u003eComplete the installation with approved mounting, communications, charging, distribution, and service components.\u003c\/p\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(230px,1fr)); gap: 10px;\"\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 10px; padding: 16px;\"\u003e\n\u003cstrong style=\"display: block; color: #1a202c; font-weight: bold; margin-bottom: 5px;\"\u003eElite Series 8D mounting hardware\u003c\/strong\u003e \u003cspan\u003eOfficial fitment support for C24230A-A securement in mobile and stationary installations.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 10px; padding: 16px;\"\u003e\n\u003cstrong style=\"display: block; color: #1a202c; font-weight: bold; margin-bottom: 5px;\"\u003eVictron Cerbo GX or Ekrano GX\u003c\/strong\u003e \u003cspan\u003eSystem control, DVCC, alarms, local display, and VRM remote monitoring.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 10px; padding: 16px;\"\u003e\n\u003cstrong style=\"display: block; color: #1a202c; font-weight: bold; margin-bottom: 5px;\"\u003eIncluded: Epoch\/Victron communication harness\u003c\/strong\u003e \u003cspan\u003eUse the specified grey RJ45 BMS lead and battery daisy-chain harness rather than assuming a generic pinout.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 10px; padding: 16px;\"\u003e\n\u003cstrong style=\"display: block; color: #1a202c; font-weight: bold; margin-bottom: 5px;\"\u003eProperly sized DC distribution\u003c\/strong\u003e \u003cspan\u003eBusbars, disconnect, conductors, lugs, source protection, branch fuses, and precharge appropriate to the system.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 10px; padding: 16px;\"\u003e\n\u003cstrong style=\"display: block; color: #1a202c; font-weight: bold; margin-bottom: 5px;\"\u003e24V lithium-compatible charge sources\u003c\/strong\u003e \u003cspan\u003eInverter\/charger, MPPT solar controllers, AC charger, and DC-DC equipment programmed to Epoch settings.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-radius: 10px; padding: 16px;\"\u003e\n\u003cstrong style=\"display: block; color: #1a202c; font-weight: bold; margin-bottom: 5px;\"\u003eReplacement Eaton JJN-300 fuse\u003c\/strong\u003e \u003cspan\u003eKeep only the exact approved Class-T fuse and service procedure available for qualified maintenance.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- ABYC note --\u003e\n\u003csection style=\"background: #FFFFFF; border: 1px solid #E2E8F0; border-left: 5px solid #2E91E5; border-radius: 14px; padding: 22px; margin: 32px 0;\"\u003e\n\u003ch2 style=\"font-size: 18px; font-weight: 600; letter-spacing: 0.05em; text-transform: uppercase; color: #1a202c; margin: 0 0 12px 0; line-height: 1.35;\"\u003eMarine and ABYC installation note\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 14px 0; color: #2e91e5; font-weight: 600;\"\u003eA built-in Class-T fuse supports system safety—but compliance applies to the complete installation.\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003eInstallers searching for an ABYC-compliant marine battery system should evaluate the full design rather than the battery alone. Disconnect accessibility, source and branch protection, unfused conductor length, cable ampacity, securement, ignition-protection requirements, grounding, labeling, compartment conditions, and commissioning must all be addressed under the applicable standards and vessel design.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c!-- Technical specs --\u003e\u003c!-- Installation note --\u003e\n\u003csection style=\"background: linear-gradient(135deg,#031725 0%,#06253D 100%); color: #ffffff; border-radius: 14px; padding: 26px; margin: 32px 0; border: 1px solid rgba(46,145,229,0.35);\"\u003e\n\u003ch2 style=\"font-size: 18px; font-weight: 600; letter-spacing: 0.05em; text-transform: uppercase; color: #ffffff; margin: 0 0 12px 0; line-height: 1.35;\"\u003eInstallation and commissioning note\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 14px 0; color: #7dc8ff; font-weight: 600;\"\u003eSecure the battery first, then engineer conductors, protection, precharge, charging, communications, and documentation.\u003c\/p\u003e\n\u003cp style=\"margin: 0; color: #ffffff;\"\u003eInstall on a flat rigid surface with service access to terminals, the fuse area, switch, and communication ports. Use approved restraints, short protected source conductors, appropriate busbars and lugs, controlled precharge for large capacitive loads, and equal-length conductors in parallel banks. Commission Victron communications, DIP settings, current limits, charging voltages, alarms, and module counts before placing loads into service.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c!-- FAQ --\u003e\u003c!-- FAQ schema --\u003e \u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What does “V2-T” mean, and why is the Class-T fuse important?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The V2-T design adds a user-serviceable 300A Eaton Class T fuse to the V2 Elite platform. The C24230A-A uses an Eaton Bussmann JJN-300 rated at 300A with a 20kA interrupting rating at 160V DC, under a protected service cover on the lid. It reduces fault energy at the battery outlet, but it does not replace the main disconnect, downstream conductor protection, branch fusing, or the rest of a code-compliant system design.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"If the internal Class-T fuse opens, is the battery ruined?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No. The fuse is replaceable through the protected service-access area. Isolate every source and load, open the main disconnect, verify the system is de-energized, identify and correct the fault, and replace the fuse only with the exact approved model and rating. Restore all covers and seals before returning the battery to service; qualified service is strongly recommended.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does the 24V V2-T connect directly to a Victron system?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, when installed with Epoch's specified communication harness and configuration. The battery communicates at 500kbit\/s over CAN. Connect the designated grey RJ45 lead to the appropriate BMS-Can or configurable VE.Can port on a compatible Cerbo GX or Ekrano GX, set the port as instructed, enable DVCC, and select Epoch as the controlling BMS and battery monitor. Do not assume every generic RJ45 cable has the required battery-side pinout.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can I connect these batteries in series or parallel?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The C24230A-A user manual supports up to two batteries in series (51.2V nominal, 58.0V at full charge) or up to sixteen in parallel (3,680Ah). Mixed series-parallel banks are not supported. Use C24230A-A batteries of the same age, capacity and state of charge (fully charge each one on its own first), set the DIP switches for the bank, and follow the manual for the selected topology.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How large can a parallel V2-T battery bank become?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Sixteen 5.888kWh batteries provide about 94.21kWh of nominal stored energy and 3,680Ah at 25.6V nominal. Every battery output is a separate source and requires an engineered connection to common busbars, equal-length conductors, appropriate source and branch protection, secure mounting, communication configuration, and professional commissioning.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How does internal self-heating work in freezing conditions?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The battery includes a 153.6W heater controlled by the BMS. The user manual lists low-temperature charge protection at 0°C, heater activation during charging at 5°C, and heater deactivation at 10°C. Available incoming charge energy warms the cells before normal charging proceeds. Charging equipment must still be programmed correctly and provide enough current for heating and charging.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is the battery completely waterproof?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No. The enclosure is IP67 rated—dust-tight and tested for temporary immersion up to 1 meter for up to 30 minutes when all seals and glands are correctly installed. It is not rated for water jets, pressure washing or continuous submersion. Install the battery where it stays dry in normal use, and make sure all harness connectors are fully seated.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What size inverter can one 24V 230Ah V2-T battery support?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"At 25.6V nominal and 115A continuous discharge, the battery provides approximately 2.94kW of nominal DC output before inverter losses. Inverter DC input current ≈ AC load ÷ (25.6V × inverter efficiency): a 2,000W load through a 90%-efficient inverter draws about 87A. If an inverter's continuous DC input can exceed 115A, add batteries in parallel. Final inverter sizing must account for efficiency, surge demand, cable voltage drop, ambient temperature, precharge requirements, downstream protection, and the battery's current limits.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does the built-in fuse make the installation ABYC compliant?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No single component makes an entire installation ABYC compliant. The integrated Class T fuse reduces fault energy at the battery outlet but does not replace the main fuse, disconnect or branch protection; compliance depends on the complete system—including disconnect location, unfused conductor length, conductor ampacity, overcurrent protection, ignition-protection requirements where applicable, securement, routing, labeling, grounding, and qualified installation.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What can I monitor through Bluetooth?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The Epoch Cloud app (iOS and Android) shows state of charge, cell voltage, temperature, charge and discharge cycles and system health alerts, over Bluetooth 4.0 through the included battery gauge (stay within about 10 m). The gauge also shows state of charge. In a Victron-managed system, the GX device becomes the central view for battery and system data.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What are the dimensions and weight?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The user manual lists the C24230A-A at 20.86 inches long by 8.65 inches wide by 12.06 inches high, with a weight of 98.9 pounds. It uses M8 terminals with a published terminal torque of 12N·m (8.85lb-ft). Confirm compartment clearance, service access, cable bend radius, and mounting hardware before ordering.\"\n      }\n    }\n  ]\n}\n  \u003c\/script\u003e\n\u003c\/div\u003e","brand":"Epoch Batteries","offers":[{"title":"Default Title","offer_id":67762432081972,"sku":"C24230A-A","price":2599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0551\/8462\/1620\/files\/ChatGPT_Image_Sep_20_2026_04_05_11_AM_091749b5-7947-4ceb-923c-ef6a16ff7bdc.png?v=1792971252","url":"https:\/\/offgridstores.com\/products\/24v-230ah-v2-t-elite-series-lifepo4-battery-5-89kwh","provider":"Off Grid Stores","version":"1.0","type":"link"}